Honeywell
Honeywell 900H03-0001 8-Channel AC Digital Output Module
Manufacturer: Honeywell
Product No.: 900H03-0001
Product Type: Digital Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 1300g
Shipping port: Xiamen
Warranty: 12 months
Product Overview
The Honeywell 900H03-0001 is an 8-channel AC digital output module designed for the ControlEdge HC900 controller family. Featuring Triac outputs rated for 85–240 VAC, this module provides isolated, high-voltage switching for AC loads such as solenoid valves, contactor coils, indicator lamps, and motor starters. With individual channel isolation, built-in surge protection, and compact design, the 900H03-0001 is ideal for industrial automation applications requiring reliable AC load control.
Key Features
- 8 isolated Triac output channels for AC load switching
- Wide voltage range: 85–240 VAC per channel
- High current capacity: up to 2 A per channel
- Individual channel isolation for noise immunity and safety
- Built-in surge protection for inductive load switching
- Individual LED status indicators for each output channel
- Compact modular design for HC900 rack mounting
Technical Specifications
- Model: 900H03-0001
- Product Type: 8-Channel AC Digital Output Module
- Series: ControlEdge HC900
- Output Channels: 8
- Output Type: Triac (isolated)
- Operating Voltage: 85–240 VAC
- Output Voltage: 120–240 VAC (line voltage following)
- Load Current per Channel: 0–2 A
- Power Requirements: 5 VDC @ 218 mA
- Isolation: Channel-to-channel and channel-to-system isolation
- Surge Protection: Built-in snubber circuit for inductive loads
- Status Indicators: Individual LED per channel
- Dimensions (L × W × H): 100 × 70 × 25 mm (3.9" × 2.8" × 1.0")
- Weight: Approx. 0.3 kg
- Operating Temperature: 0°C to +60°C
- Storage Temperature: −40°C to +85°C
- Humidity: 5% to 95% RH (non-condensing)
- Mounting: HC900 rack slot
- Certifications: CE, UL, CSA
Typical Applications
- AC solenoid valve control
- Contactor and relay coil driving
- AC indicator lamp and alarm horn control
- Motor starter control circuits
- Heater and fan AC load switching
FAQ
Q: What type of outputs does the 900H03-0001 provide?
A: It provides 8 Triac outputs for switching AC loads in the 85–240 VAC range.
Q: What is the maximum current per channel?
A: Each channel supports up to 2 A of AC load current.
Q: Are the outputs isolated?
A: Yes. Each channel features individual isolation from the system and from other channels, providing excellent noise immunity and safety.
Q: Can this module drive inductive loads?
A: Yes. The built-in snubber circuit protects the Triac outputs when switching inductive loads such as contactor coils and solenoids.
Q: What is the difference between 900H03-0001 and 900H03-0202?
A: The 900H03-0001 is a legacy revision. The 900H03-0202 is a current-generation equivalent. Both provide 8-channel 120/240 VAC Triac outputs. Verify controller firmware compatibility.
Installation Guide
- Power Off: De-energize the HC900 rack before installing the 900H03-0001.
- Slot Insertion: Insert the module into an available I/O slot and press firmly until the retention clips engage.
- Field Wiring: Connect AC loads to the module terminals using appropriate high-voltage wiring (typically 14–18 AWG). Ensure proper torque on terminal screws.
- Load Verification: Verify each load does not exceed 2 A continuous. For inductive loads, ensure the snubber circuit is adequate or add external protection if necessary.
- Fusing: Install external fuses or circuit breakers for each channel to protect against overload conditions.
- Status Check: Power on the rack and activate each output via the PLC program. Confirm the corresponding LED illuminates and the load operates correctly.
Selection Tips
- Choose the 900H03-0001 for 8-channel AC load switching with individual channel isolation.
- If you need more AC output channels, consider the 900H03-0202 (current revision) or add additional 900H03 modules.
- For DC output switching, use the 900H32-0302 (24 VDC, 32-channel) or 900H02-0102 (24 VDC, 16-channel).
- For relay outputs (isolated dry contacts), use the 900H01-0202 relay output module.
- Always install external fusing per channel to protect the Triac outputs from overload.
- Ensure total rack power budget accounts for the 218 mA @ 5 VDC module draw.
Return policy
We aim to provide reliable products and a smooth purchasing experience. If there is a problem with your order, please contact us and we will assist according to our Refund Policy.
Shipping
We provide international shipping options to meet different delivery requirements. Please review details regarding methods and timelines in our Shipping Policy.
Warranty
We provide a 12-month warranty for all products, subject to normal use and proper installation.
You may also like
Product Guide
Mitigating SCADA Performance Drops During Shift Transitions
Mitigating SCADA Performance Drops During Shift Transitions
Optimizing SCADA Performance: Why Remote Clients Experience Lag
Optimizing SCADA Performance: Why Remote Clients Experience Lag