Honeywell
Honeywell CC-PAIH02 HART Analog Input Module
Manufacturer: Honeywell
Product No.: CC-PAIH02
Product Type: Analog Input
Product Origin: USA
Payment:T/T, Western Union
Weight: 1000g
Shipping port: Xiamen
Warranty: 12 months
Overview
The Honeywell CC-PAIH02 (part number 51405038-375) is a 16-Channel HART Analog Input Module for Honeywell Experion™ PKS Series C distributed control systems. It accepts current and voltage inputs with full HART communication capability, enabling remote device diagnostics and multivariable instrument integration.
Technical Specifications
- Manufacturer: Honeywell
- Model: CC-PAIH02
- Part Number: 51405038-375
- Type: 16-Channel HART Analog Input Module
- Input Channels: 16 (12 single-ended / 4 differential)
- Input Types: Voltage, current (2-wire or self-powered transmitters)
- Input Ranges: 0–5 V, 1–5 V, 0.4–2 V, 4–20 mA (through 250 Ω)
- A/D Resolution: 16 bits (majority of sources); 12–16 bits (some sources)
- HART Protocol: HART 5/7 (multivariable capable)
- Common Mode Rejection Ratio (CMRR): 70 dB (DC to 60 Hz, 500 Ω imbalance)
- Common Mode Voltage: −6 to +5 V peak (DC to 60 Hz)
- Normal Mode Rejection Ratio (NMRR): 19 dB (at 60 Hz)
- Normal Mode Filter: Single-pole RC, −3 dB @ 6.5 Hz
- Maximum Normal Mode Input: ±30 V (differential, no damage)
- Crosstalk: −60 dB (DC to 60 Hz, channel-to-channel)
- Input Impedance (voltage): >10 MΩ
- Input Scan Rate: 50 ms
- Hardware Accuracy: ±0.075 % FS (23.5 °C ± 2 °C); ±0.15 % FS (0–60 °C)
- Power Consumption: 60 W max
- Weight: 0.54 kg (1.20 lb)
Environmental & Safety Ratings
- Operating Temperature: 0 °C to +60 °C
- Storage Temperature: −40 °C to +70 °C
- Humidity: 5 % – 95 % RH non-condensing
- Coating: G3 environmental coating
- Compliance: CE, UL, CSA, RoHS
Key Features
- 16-channel HART analog input for smart transmitter integration
- Full HART 5/7 protocol support for remote diagnostics and configuration
- Multivariable capability for advanced device data retrieval
- 16-bit resolution for precise signal conversion
- Open-wire detection and bad PV identification
- Optional redundancy for fault-tolerant operation
- Non-incendive field power for hazardous area transmitters
- Supersedes older CC-PAIH01 module
FAQ
Q: What is the difference between CC-PAIH01 and CC-PAIH02?
A> CC-PAIH02 supersedes CC-PAIH01. CC-PAIH02 supports differential inputs on all 16 channels; CC-PAIH01 only supports differential on channels 13–16. CC-PAIH02 also offers enhanced HART processing.
Q: Does every channel support HART?
A> Yes, all 16 channels are HART-enabled for communication with smart transmitters and multivariable instruments.
Q: What is the maximum power consumption?
A> Maximum power consumption is 60 W under full load conditions.
Installation Guidelines
- Mount the CC-PAIH02 on the appropriate IOTA base (CC-TAIX01, CC-TAIX11, etc.).
- Connect 4–20 mA field wiring with shielded twisted-pair cable.
- Verify HART device communication via Experion PKS Device Manager.
- Configure input range, scaling, and HART parameters via Control Builder.
Selection Tips
- Choose CC-PAIH02 for HART-enabled analog input applications requiring remote device diagnostics.
- For non-HART applications, consider CC-PAIX02 to reduce cost.
- Verify your transmitters support HART protocol before ordering.
Return policy
We aim to provide reliable products and a smooth purchasing experience. If there is a problem with your order, please contact us and we will assist according to our Refund Policy.
Shipping
We provide international shipping options to meet different delivery requirements. Please review details regarding methods and timelines in our Shipping Policy.
Warranty
We provide a 12-month warranty for all products, subject to normal use and proper installation.
You may also like
Product Guide
Mitigating SCADA Performance Drops During Shift Transitions
Mitigating SCADA Performance Drops During Shift Transitions
Optimizing SCADA Performance: Why Remote Clients Experience Lag
Optimizing SCADA Performance: Why Remote Clients Experience Lag