Honeywell
Honeywell CC-PDIS01 Digital Input Sequence of Events
Manufacturer: Honeywell
Product No.: CC-PDIS01
Product Type: Digital Input
Product Origin: USA
Payment:T/T, Western Union
Weight: 1000g
Shipping port: Xiamen
Warranty: 12 months
Overview
The Honeywell CC-PDIS01 (part number 51405042-175/176) is a 32-Channel Digital Input Sequence of Events (DISOE) Module for Honeywell Experion™ PKS Series C distributed control systems. It captures discrete input state changes with 1 ms timestamp resolution, enabling precise event sequencing for safety diagnostics and root-cause analysis.
Technical Specifications
- Manufacturer: Honeywell
- Model: CC-PDIS01
- Part Number: 51405042-175 / 51405042-176
- Type: 32-Channel Digital Input Sequence of Events (DISOE)
- Input Channels: 32
- Input Voltage Range: 18–30 VDC
- ON Sense Voltage/Current: ≥13 VDC or ≥3 mA
- OFF Sense Voltage/Current: ≤5 VDC or ≤1.2 mA
- Input Impedance: 4.2 kΩ
- SOE Resolution: 1 ms
- Input Scan Rate: 20 ms (Normal); 5 ms (Low Latency)
- Galvanic Isolation: 1500 VAC RMS or ±1500 VDC
- Isolation Technique: Optical (in IOM)
- Power Consumption: ~3.5 W (typical)
- Weight: ~0.3 – 1.2 kg
Key Features
- Three modes of operation: Normal (20 ms), SOE (1 ms + 20 ms PV), Low Latency (5 ms)
- 1 ms SOE resolution for precise event timestamping
- Open wire detection (Normal mode) for diagnostic integrity
- Optional redundancy for high-availability applications
- Internal or external field power selection
- On-board excitation power (no marshalling required)
- Supplies non-incendive field power for hazardous areas
FAQ
Q: What is the SOE resolution?
A> The CC-PDIS01 provides 1 millisecond timestamp resolution for Sequence of Events applications.
Q: What IOTA bases are compatible?
A> Compatible IOTAs include CC-TDIL01 (non-redundant, 9"), CC-TCML11 (redundant, 12"), CC-GDIL11 (redundant, 12"), CC-GDIL21 (non-redundant, 6").
Q: Can I use this for standard digital input without SOE?
A> Yes, the Normal mode (20 ms scan) operates as a standard 32-channel DI module without SOE timestamping.
Installation Guidelines
- Mount the CC-PDIS01 on the appropriate IOTA base (CC-TDIL01, CC-TCML11, etc.).
- Configure internal or external field power via jumper settings.
- Connect 24 VDC discrete field wiring to the terminal blocks.
- Configure SOE mode via Experion PKS Control Builder if timestamping is required.
- Verify input status and SOE timestamps via Experion PKS diagnostics.
Selection Tips
- Choose CC-PDIS01 when you need 1 ms SOE resolution for trip diagnostics or event sequencing.
- For standard digital input without SOE, a standard DI module may be more cost-effective.
- Verify IOTA base model matches your redundancy and space requirements.
Return policy
We aim to provide reliable products and a smooth purchasing experience. If there is a problem with your order, please contact us and we will assist according to our Refund Policy.
Shipping
We provide international shipping options to meet different delivery requirements. Please review details regarding methods and timelines in our Shipping Policy.
Warranty
We provide a 12-month warranty for all products, subject to normal use and proper installation.
You may also like
Product Guide
Mitigating SCADA Performance Drops During Shift Transitions
Mitigating SCADA Performance Drops During Shift Transitions
Optimizing SCADA Performance: Why Remote Clients Experience Lag
Optimizing SCADA Performance: Why Remote Clients Experience Lag