Honeywell
Honeywell FC-SDO-1624 Safety Digital Input Module
Manufacturer: Honeywell
Product No.: FC-SDO-1624
Product Type: Safety Digital Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 400g
Shipping port: Xiamen
Warranty: 12 months
Product Description
The FC-SDO-1624 is a high-integrity digital input module designed for use within the Honeywell Fail-Safe Controller (FSC) and Safety Manager ecosystems. Despite its model designation, this module functions as a 16-channel discrete input interface, providing a reliable connection between field-mounted safety devices and the central safety logic solver.
Built for high-availability Safety Instrumented Systems (SIS), the FC-SDO-1624 is widely deployed in high-risk industries such as oil & gas, chemical processing, and petrochemical production. Its robust design ensures accurate state detection of safety-critical signals under harsh electrical and environmental conditions.
Operating across a wide 18–30 VDC input range, the module maintains dependable signal acquisition even during power fluctuations. Low per-channel current consumption minimizes thermal load on the safety rack, while its IP65-rated construction and extended temperature tolerance allow continuous operation in extreme climates and demanding industrial atmospheres.
Technical Specifications
| Item | Specification |
|---|---|
| Model Number | FC-SDO-1624 |
| Module Type | Digital Input Module |
| Primary System | Honeywell FSC (Fail-Safe Controller) |
| Channel Density | 16 Digital Input Channels |
| Nominal Input Voltage | 24 VDC |
| Operating Voltage Range | 18 to 30 VDC |
| Channel Current Draw | 2 mA per channel |
| Response Time | < 25 ms |
| Ingress Protection | IP65 |
| Operating Temperature Range | –40°C to +70°C |
Safety System Applications
The FC-SDO-1624 serves as a foundational element in automated protection layers, continuously monitoring the status of safety-critical devices such as:
-
Emergency Shutdown (ESD): Manual call points, E-stop pushbuttons, and safety interlocks
-
Fire & Gas (F&G) Systems: Discrete inputs from gas detectors and flame sensors
-
Burner Management Systems (BMS): Flame scanners, valve limit switches, and permissive signals
Technical FAQ
What makes the FC-SDO-1624 suitable for hazardous areas?
The module is certified to ATEX and CSA standards, meeting stringent electrical and thermal requirements for hazardous locations when installed within an appropriately rated enclosure.
How does the < 25 ms response time affect system safety?
A response time below 25 ms allows the safety logic solver to recognize field state changes—such as an emergency stop—almost instantaneously, ensuring compliance with required Process Safety Time (PST) limits for hazard mitigation.
Return policy
We aim to provide reliable products and a smooth purchasing experience. If there is a problem with your order, please contact us and we will assist according to our Refund Policy.
Shipping
We provide international shipping options to meet different delivery requirements. Please review details regarding methods and timelines in our Shipping Policy.
Warranty
We provide a 12-month warranty for all products, subject to normal use and proper installation.
You may also like
Product Guide
What is an Interposing Relay in a PLC System?
What is an Interposing Relay in a PLC System?
Rockwell CompactLogix 5380 Controller: Advancing Smart Manufacturing with Precision and Connectivity
Rockwell CompactLogix 5380 Controller: Advancing Smart Manufacturing with Precision and Connectivity