Honeywell
Honeywell FS-TSAI-1620M Safe Analog Input Field Termination Assembly (FTA)
Manufacturer: Honeywell
Product No.: FS-TSAI-1620M
Product Type: TERMINATION ASSEMBLY
Product Origin: USA
Payment:T/T, Western Union
Weight: 300g
Shipping port: Xiamen
Warranty: 12 months
Product Overview
The Honeywell FS-TSAI-1620M is a Safe Analog Input Field Termination Assembly (FTA) designed for Honeywell Safety Manager systems. It provides 16 channels of 4-20 mA analog input with integrated safety diagnostics, serving as the critical interface between field transmitters (pressure, temperature, flow, level) and the safety controller. Engineered for SIL-rated applications, this FTA ensures accurate analog signal acquisition with built-in line monitoring and fault detection.
Key Features
- 16 Analog Input Channels: 4-20 mA loop-powered or externally powered transmitter support
- Safe Analog Input: SIL-rated signal conditioning for safety instrumented systems
- System Interconnection: SIC cable interface to redundant SAI-1620M I/O modules
- Line Monitoring: Detects open circuits, short circuits, and out-of-range signals
- DIN Rail Mounting: Universal snap-in for TS32/TS35 rails
- Compact Design: Space-efficient for dense control panel layouts
Technical Specifications
- Model: FS-TSAI-1620M (also FC-TSAI-1620M)
- Type: Safe Analog Input FTA
- Channels: 16 analog inputs
- Signal Range: 4-20 mA
- Input Type: Loop-powered or externally powered 2-wire/4-wire transmitters
- Resolution: 12-bit or higher (system dependent)
- Accuracy: ±0.1% typical
- Line Monitoring: Open circuit, short circuit, out-of-range detection
- Dimensions: 60 × 70 × 58 mm (L × W × H)
- DIN Rail: TS32 / TS35 × 7.5
- Wire Size: Max 2.5 mm² (AWG 14)
- Strip Length: 7 mm (0.28 in)
- Tightening Torque: 0.5 Nm (0.37 ft-lb)
- Operating Temperature: -40°C to +70°C
- Approvals: CE, TÜV, UL, CSA, FM
Installation Guide
- DIN Rail Mount: Snap FTA onto TS32/TS35 rail in control cabinet
-
Transmitter Wiring: Connect 4-20 mA transmitters to screw terminals:
- Loop-powered: Connect +24V, signal return, and common
- Externally powered: Connect signal + and signal - only
- SIC Cable: Plug SIC-C-12 system interconnection cable into SIC connector
- Redundancy: For redundant SAI-1620M modules, connect both FTAs to paired I/O modules
- Shield Grounding: Connect cable shields to single-point ground to avoid ground loops
FAQ
Q: Can this FTA support HART protocol?
A: The FS-TSAI-1620M supports 4-20 mA analog signals. For HART digital communication overlay, verify compatibility with specific I/O module revisions or use dedicated HART modules.
Q: What is the difference between FS-TSAI-1620M and FC-TSAI-1620M?
A: They are functionally identical. "FS-" and "FC-" prefixes denote manufacturing batch or regional variants within the same product family.
Q: How does line monitoring work?
A: The FTA continuously monitors loop current. Open circuits (current < 3.6 mA), short circuits, and over-range conditions (> 21 mA) are detected and reported to the safety controller.
Selection Tips
- Use for 4-20 mA transmitter applications in Safety Manager systems
- Verify transmitter power requirements (loop-powered vs. externally powered)
- Ensure paired I/O module is SAI-1620M installed in the chassis
- For RTD/thermocouple inputs, use dedicated temperature input modules instead
- Consider redundant SAI-1620M pairs for SIL 3 applications
Return policy
We aim to provide reliable products and a smooth purchasing experience. If there is a problem with your order, please contact us and we will assist according to our Refund Policy.
Shipping
We provide international shipping options to meet different delivery requirements. Please review details regarding methods and timelines in our Shipping Policy.
Warranty
We provide a 12-month warranty for all products, subject to normal use and proper installation.
You may also like
Product Guide
Mitigating SCADA Performance Drops During Shift Transitions
Mitigating SCADA Performance Drops During Shift Transitions
Optimizing SCADA Performance: Why Remote Clients Experience Lag
Optimizing SCADA Performance: Why Remote Clients Experience Lag