  • Product Type: Exciter Contact Terminal Board

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 450g

  • Shipping port: Xiamen

  • Warranty: 12 months

Special offer ends!
00 :
00 :
00

Configured for excitation control interfacing in Mark VI and Mark VIe Speedtronic turbine control systems, the GE IS200ECTBG1ADE (base model IS200ECTB) provides direct physical and electrical execution between field contact wiring and internal I/O packs. Signal routing occurs via hardened terminal blocks and shielded interconnects, supporting discrete contact input acquisition and breaker status monitoring without protocol translation.

Hardware Specifications

Parameter Specification
Model Brand General Electric (GE)
Origin USA
Weight 0.45 kg
Dimensions 280 mm x 160 mm x 25 mm
Operating Temp -30 degC to +65 degC
Power Consumption < 5 W (passive board, no active power draw)
System Compatibility Mark VI / Mark VIe Speedtronic
Connector Type Barrier terminal blocks, ribbon/D-shell cables

Backplane Bus Communication and Firmware Flash Considerations

The IS200ECTBG1ADE interfaces directly with Mark VIe I/O packs over a deterministic backplane bus. Bus communication velocity is fixed at system clock rate; no user-adjustable parameters exist. Firmware flash compatibility is governed by the assigned I/O pack processor type and must match the control system’s release baseline to prevent configuration rejection during download. Mismatched firmware will halt signal mapping until corrected.

Frequently Asked Questions

Q: Can the IS200ECTBG1ADE be hot-swapped?

A: No. All field wiring and control system power must be removed prior to removal or installation to avoid damaging connected I/O electronics.

Q: Does the board require calibration after replacement?

A: No calibration is required; verification is limited to contact continuity checks and correct terminal torque application.

Q: Is the board compatible with both Mark VI and Mark VIe systems?

A: Yes, provided the associated I/O pack and system firmware support the same hardware revision level.

Field Installation Guidelines

Mount vertically in the designated control cabinet channel using factory-specified sheet metal brackets. Torque terminal screws to 0.8 Nm unless otherwise stated by site standards. Maintain separation between high-voltage field wiring and low-level signal leads to reduce inductive coupling. Ground shield terminations at the panel entry point only, ensuring continuous shield integrity without intermediate breaks. Verify all circuits are de-energized before termination.