Skip to product information
KJ3225X1-BK1 | Emerson DeltaV S-Series RTD / Resistance Input Card

Emerson

KJ3225X1-BK1 | Emerson DeltaV S-Series RTD / Resistance Input Card

10 left
  • Manufacturer: Emerson

  • Product No.: KJ3225X1-BK1

  • Product Type: RTD Input Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 200g

  • Shipping port: Xiamen

  • Warranty: 12 months

Special offer ends!
00 :
00 :
00

Overview

The Emerson KJ3225X1-BK1 is an S-Series Analog RTD / Resistance Input Module for the DeltaV™ distributed control system. It provides 8 channels of precise temperature measurement using RTD and resistance inputs, certified for hazardous-area operation.

Technical Specifications

  • Manufacturer: Emerson
  • Model: KJ3225X1-BK1
  • Type: S-Series RTD / Resistance Input Card
  • Input Channels: 8 channels
  • Input Type: RTD and resistance measurements
  • Local Bus Power: 12 VDC at 160 mA
  • Terminal Block Key Position: C3
  • Weight: 0.70 lbs (318 g)

Environmental & Safety Ratings

  • Operating Temperature: −40 °C to +70 °C
  • Shock: 10 g, ½ sine wave for 11 ms
  • Vibration: 1 mm peak-to-peak (2–13.2 Hz); 0.7 g (13.2–150 Hz)
  • Relative Humidity: 5 % – 95 % non-condensing
  • Airborne Contaminants: ISA-S71.04-1985 Class G3
  • Hazardous Area: ATEX II 3G Ex ec IIC Gc; II 3G Ex nA nL IIC Gc; IECEx FMG 19.0019U; FM Class I Div. 2 Groups A,B,C,D; Class I Zone 2 AEx/Ex ec IIC Gc

Key Features

  • 8-channel RTD and resistance input for temperature measurement
  • Rotary keying system ensures compatibility with correct terminal block
  • No user-serviceable parts—maintenance-free operation
  • Certified for hazardous atmospheres (ATEX, IECEx, FM)

FAQ

Q: What sensor types does this module support?
A: It supports RTD (Resistance Temperature Detector) and general resistance measurements across 8 input channels.

Q: What terminal block do I need?
A: Use a rotary-keyed terminal block set to position C3.

Q: Can I remove this module while the system is running?
A: Field power must be removed before module removal. System power must be de-energized for safe insertion or removal.

Installation Guidelines

  1. Set the terminal block key to C3.
  2. Install the card into an S-Series carrier slot.
  3. Connect RTD or resistance sensor wiring per the DeltaV wiring manual.
  4. For "nL" installations, an I/O loop assessment is required per hazardous-area guidelines.

Selection Tips

  • Choose KJ3225X1-BK1 when you need RTD or resistance temperature measurement in DeltaV S-Series.
  • Verify your sensor type (2-wire, 3-wire, or 4-wire RTD) is supported by this module revision.
  • Confirm hazardous-area certification markings for your region.