MVI56-MCMR | Prosoft Modbus Communication Module

PROSOFT

MVI56-MCMR | Prosoft Modbus Communication Module

10 left
  • Manufacturer: PROSOFT

  • Product No.: MVI56-MCMR

  • Product Type: Communication Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 1360g

  • Shipping port: Xiamen

  • Warranty: 12 months

Special offer ends!
00 :
00 :
00

Product Overview

The ProSoft MVI56-MCMR is a dual-port Modbus RTU/ASCII Communication Module specifically optimized for remote rack installations in Rockwell Automation ControlLogix systems. It features two fully independent serial channels with DB9 connectors, supporting RS-232/RS-422/RS-485 software-selectable interfaces. Unlike the standard MVI56-MCM, the MCMR uses a compact data block approach that minimizes backplane bandwidth usage, making it ideal for installations across ControlNet or EtherNet/IP remote I/O networks.

Key Technical Specifications

  • Product Type: Dual-Port Modbus RTU/ASCII Communication Module (Remote Optimized)
  • Series: ProSoft MVI56
  • Platform: Allen-Bradley ControlLogix
  • Serial Ports: 2 × DB9 female connectors
  • Interface Types: RS-232 / RS-422 / RS-485 (software configurable)
  • Protocol Support: Modbus RTU, Modbus ASCII
  • Channel Independence: 2 fully independent channels with different baud rates and protocols
  • Baud Rate Range: 300 bps to 115.2 kbps
  • Data Capacity: Up to 10,000 16-bit registers (internal storage)
  • Backplane: 1756 ControlLogix (optimized for remote racks)
  • Power Consumption: ~500 mA @ 5V DC (typical, dual channel full load)
  • Configuration Port: 1 × RJ45 (10/100 Mbps) for Web server and diagnostics
  • Serial Settings: None/Odd/Even parity, 5-8 data bits, 1-2 stop bits, RTS delay adjustable
  • Configuration Tool: ProSoft Configuration Builder (PCB)
  • Operating Temperature: 0°C to +60°C
  • Storage Temperature: -40°C to +85°C
  • Origin: USA

Key Features

  • Remote Rack Optimized: Compact data block minimizes bandwidth over ControlNet/EtherNet/IP
  • Dual Independent Channels: Each port runs different baud rates and protocols simultaneously
  • High-Speed Communication: Up to 115.2 kbps for demanding applications
  • Large Internal Database: 10,000-word storage for extensive device data
  • Web-Based Diagnostics: RJ45 configuration port with built-in web server
  • Flexible Configuration: PCB software with import/export capability
  • Master/Slave Flexibility: Each port independently configurable

Critical Installation Note — Data Block Approach

Unlike standard MVI56-MCM, the MCMR uses a compact data block that does NOT automatically map to PLC I/O tags. You MUST use ProSoft's Add-On Instruction (AOI) or custom function blocks to read data from the module. Without periodic MCM_READ calls in ladder logic, the module LEDs will show green but data will remain at initial values.

RS-485 Wiring Best Practices

  • For runs >100m or >10 nodes, install 120Ω termination resistors at both ends of the bus
  • MVI56-MCMR does NOT have built-in termination jumpers — external resistors required
  • Verify A/B polarity with multimeter (A should be ~2-6V higher than B when idle)

Applications

  • Cross-facility energy data acquisition (multi-kilometer installations)
  • Mixed-protocol packaging lines (Modbus RTU + ASCII simultaneously)
  • Remote SCADA concentrator applications
  • Bandwidth-constrained ControlNet/EtherNet/IP remote I/O

Installation Guide

  1. Install in 1756 ControlLogix slot (local or remote rack)
  2. Connect DB9 serial cables to Port 1 and Port 2
  3. Set jumpers for RS-232/422/485 as required
  4. Configure baud rate, parity, and protocol per port via PCB
  5. Import AOI into Studio 5000 and add periodic MCM_READ calls
  6. Map internal database to controller tags
  7. Verify data flow via web diagnostics

FAQ

Q: What is the difference between MVI56-MCM and MVI56-MCMR?
A: MCMR is optimized for remote racks with compact data blocks; MCM is for local racks with automatic I/O mapping.

Q: Why is my MCMR showing green LEDs but no data?
A: You must use AOI or custom function blocks to read data. The module does not auto-map to I/O tags.

Q: Does it support floating-point data?
A: Yes, supports Enron and Daniel floating-point formats.

Model Selection Tips

  • MVI56-MCMR = Remote-optimized Modbus module for ControlNet/EtherNet/IP remote I/O
  • For local rack with auto I/O mapping, use MVI56-MCM
  • For extended temperature, use MVI56E-MCMXT
  • For Modbus TCP/IP, use MVI56E-MNETC
  • Always verify AOI implementation in ladder logic for MCMR
Return policy

​We aim to provide reliable products and a smooth purchasing experience. If there is a problem with your order, please contact us and we will assist according to our Refund Policy.

Shipping

We provide international shipping options to meet different delivery requirements. Please review details regarding methods and timelines in our Shipping Policy.

Warranty

We provide a 12-month warranty for all products, subject to normal use and proper installation.

You may also like