Emerson
Westinghouse Ovation 5X00119G03 RTD Input Module 8CH
Manufacturer: Emerson
Product No.: 5X00119G03
Product Type: Interface Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 200g
Shipping port: Xiamen
Warranty: 12 months
Emerson Ovation 5X00119G03 – 8-Channel High-Precision RTD Input Module
The Emerson Ovation 5X00119G03 is an 8-channel high-precision RTD input module for advanced temperature measurement in the Ovation DCS. It builds upon the G02 revision with enhanced diagnostics, wider compatibility, and integrated cold-junction compensation for thermocouple adapters.
- Channels: 8 RTD inputs
- Supported RTD Types: Pt100 (−200°C to +850°C), Pt500, Pt1000, Cu50, Cu100
- Measurement Accuracy: 0.1% of span
- Resolution: 16-bit A/D conversion
- Wire Configuration: 2-wire, 3-wire, 4-wire RTD support
- Cold Junction Compensation: Integrated (for TC adapter use)
- Update Rate: 50 Hz acquisition mode
- Diagnostics: Real-time open/short sensor detection
- Isolation: Channel-to-channel and input-to-system isolation
- Power Supply: 24 VDC
- Operating Temperature: −40°C to +70°C
- Humidity: 0–95% RH non-condensing
- Hot-Swappable: Yes
- Weight: 0.4 kg
- Dimensions: 41 mm × 159 mm × 108 mm
- Certifications: CE, RoHS
Technical Specifications
| Parameter | Value |
|---|---|
| Part Number | 5X00119G03 |
| Product Type | 8-Channel High-Precision RTD Input |
| RTD Types | Pt100, Pt500, Pt1000, Cu50, Cu100 |
| Temp Range | −200°C to +850°C (Pt100) |
| Accuracy | 0.1% of span |
| Resolution | 16-bit |
| Wire Config | 2-wire, 3-wire, 4-wire |
| Update Rate | 50 Hz |
| Diagnostics | Open/short detection |
| Power | 24 VDC |
| Temp Range | −40°C to +70°C |
| Weight | 0.4 kg |
FAQ
-
G03 Improvements Over G02
G03 adds enhanced diagnostics, wider RTD type support (Cu50/Cu100), and improved isolation. It is the recommended choice for new installations. -
Cryogenic Temperature Limits
The lower limit for Pt100 is −200°C. Cryogenic applications below this limit require specialized cryogenic RTDs or diodes. -
4-Wire RTD Necessity
4-wire eliminates lead resistance errors. It is recommended for high-precision (below 0.5°C error) or long cable runs above 100 m. 3-wire is sufficient for most industrial applications. -
Direct Thermocouple Support
The module is RTD-only. With an external cold-junction compensation box, some configurations accept thermocouple inputs. For native thermocouple support, use dedicated TC modules (e.g., 1C31116G04).
Installation Guide
- Step 1: Insert 5X00119G03 into the Ovation RTD slot. Follow anti-static precautions.
- Step 2: Wire RTDs to the terminal block. For 3-wire Pt100, connect the red lead to excitation +, and the two white leads to excitation − and sense terminals.
- Step 3: In Ovation Developer Studio, select RTD type, wire mode, and temperature range. Enable open-circuit and short-circuit alarms.
- Step 4: Configure channel scaling (°C, °F, or Kelvin) and alarm setpoints (Hi/Lo, HiHi/LoLo).
- Step 5: Validate with an ice bath (0.00°C) and boiling point reference (100.00°C at sea level) for process-critical applications.
Selection Tips
Choose 5X00119G03 for new Ovation temperature monitoring projects requiring 8-channel RTD input with premium diagnostics. It is the upgrade path from legacy 1C31161G02. For 16-channel density, use 5X00120G02. For thermocouple sensors (Type K, J, T), select a dedicated thermocouple input module.
Return policy
We aim to provide reliable products and a smooth purchasing experience. If there is a problem with your order, please contact us and we will assist according to our Refund Policy.
Shipping
We provide international shipping options to meet different delivery requirements. Please review details regarding methods and timelines in our Shipping Policy.
Warranty
We provide a 12-month warranty for all products, subject to normal use and proper installation.