Skip to product information
Westinghouse Ovation 5X00119G03 RTD Input Module 8CH

Emerson

Westinghouse Ovation 5X00119G03 RTD Input Module 8CH

10 left
  • Manufacturer: Emerson

  • Product No.: 5X00119G03

  • Product Type: Interface Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 200g

  • Shipping port: Xiamen

  • Warranty: 12 months

Special offer ends!
00 :
00 :
00

Emerson Ovation 5X00119G03 – 8-Channel High-Precision RTD Input Module

The Emerson Ovation 5X00119G03 is an 8-channel high-precision RTD input module for advanced temperature measurement in the Ovation DCS. It builds upon the G02 revision with enhanced diagnostics, wider compatibility, and integrated cold-junction compensation for thermocouple adapters.

  • Channels: 8 RTD inputs
  • Supported RTD Types: Pt100 (−200°C to +850°C), Pt500, Pt1000, Cu50, Cu100
  • Measurement Accuracy: 0.1% of span
  • Resolution: 16-bit A/D conversion
  • Wire Configuration: 2-wire, 3-wire, 4-wire RTD support
  • Cold Junction Compensation: Integrated (for TC adapter use)
  • Update Rate: 50 Hz acquisition mode
  • Diagnostics: Real-time open/short sensor detection
  • Isolation: Channel-to-channel and input-to-system isolation
  • Power Supply: 24 VDC
  • Operating Temperature: −40°C to +70°C
  • Humidity: 0–95% RH non-condensing
  • Hot-Swappable: Yes
  • Weight: 0.4 kg
  • Dimensions: 41 mm × 159 mm × 108 mm
  • Certifications: CE, RoHS

Technical Specifications

Parameter Value
Part Number 5X00119G03
Product Type 8-Channel High-Precision RTD Input
RTD Types Pt100, Pt500, Pt1000, Cu50, Cu100
Temp Range −200°C to +850°C (Pt100)
Accuracy 0.1% of span
Resolution 16-bit
Wire Config 2-wire, 3-wire, 4-wire
Update Rate 50 Hz
Diagnostics Open/short detection
Power 24 VDC
Temp Range −40°C to +70°C
Weight 0.4 kg

FAQ

  1. G03 Improvements Over G02
    G03 adds enhanced diagnostics, wider RTD type support (Cu50/Cu100), and improved isolation. It is the recommended choice for new installations.
  2. Cryogenic Temperature Limits
    The lower limit for Pt100 is −200°C. Cryogenic applications below this limit require specialized cryogenic RTDs or diodes.
  3. 4-Wire RTD Necessity
    4-wire eliminates lead resistance errors. It is recommended for high-precision (below 0.5°C error) or long cable runs above 100 m. 3-wire is sufficient for most industrial applications.
  4. Direct Thermocouple Support
    The module is RTD-only. With an external cold-junction compensation box, some configurations accept thermocouple inputs. For native thermocouple support, use dedicated TC modules (e.g., 1C31116G04).

Installation Guide

  • Step 1: Insert 5X00119G03 into the Ovation RTD slot. Follow anti-static precautions.
  • Step 2: Wire RTDs to the terminal block. For 3-wire Pt100, connect the red lead to excitation +, and the two white leads to excitation − and sense terminals.
  • Step 3: In Ovation Developer Studio, select RTD type, wire mode, and temperature range. Enable open-circuit and short-circuit alarms.
  • Step 4: Configure channel scaling (°C, °F, or Kelvin) and alarm setpoints (Hi/Lo, HiHi/LoLo).
  • Step 5: Validate with an ice bath (0.00°C) and boiling point reference (100.00°C at sea level) for process-critical applications.

Selection Tips

Choose 5X00119G03 for new Ovation temperature monitoring projects requiring 8-channel RTD input with premium diagnostics. It is the upgrade path from legacy 1C31161G02. For 16-channel density, use 5X00120G02. For thermocouple sensors (Type K, J, T), select a dedicated thermocouple input module.

Return policy

​We aim to provide reliable products and a smooth purchasing experience. If there is a problem with your order, please contact us and we will assist according to our Refund Policy.

Shipping

We provide international shipping options to meet different delivery requirements. Please review details regarding methods and timelines in our Shipping Policy.

Warranty

We provide a 12-month warranty for all products, subject to normal use and proper installation.