Yokogawa
Yokogawa AFS40S Field Control Unit 16MB Vnet/ESB for CENTUM CS 3000
Manufacturer: Yokogawa
Product No.: AFS40S
Product Type: Field Control Unit
Product Origin: USA
Payment:T/T, Western Union
Weight: 1500g
Shipping port: Xiamen
Warranty: 12 months
Product Overview
The AFS40S is a field control unit (FCU) for the Yokogawa CENTUM CS 3000 production control system. It serves as the intelligence core of the field control station (FCS), executing real-time control algorithms and managing I/O communication via dual-redundant Vnet and ESB bus interfaces. With a VR5432 133 MHz RISC processor and 16 MB of main memory, the AFS40S provides reliable control for medium-scale process applications.
Key Specifications
- System: Yokogawa CENTUM CS 3000
- Processor: VR5432 RISC CPU, 133 MHz
- Main Memory: 16 MB
- Memory Backup: Battery-backed, max. 72 hours retention
- Battery Recharge Time: Minimum 48 hours
- Network Interfaces: Dual-redundant Vnet, single or dual-redundant ESB bus
- Local Node Units: Max. 10 per FCU
- Remote Node Units: Max. 9 per FCU (max. 8 per ER bus)
- FCU Status Contact: 3 terminals (NC, NO, C), 250 V AC / 30 V DC, max. 2 A
- Mounting: Cabinet-integrated
- Operating Temperature: -20°C to +60°C
- Power Supply: 100–120 V AC, 220–240 V AC, or 24 V DC (suffix dependent)
Features & Benefits
- Proven RISC Architecture: The VR5432 133 MHz processor delivers deterministic control execution for continuous and batch processes.
- Dual-Redundant Vnet: Redundant control network ensures uninterrupted communication with operator stations and peer controllers.
- Flexible ESB Bus: Supports single or dual-redundant ESB bus configurations to match availability requirements and budget constraints.
- 72-Hour Memory Backup: Battery-backed RAM retains control programs and historical data during power failures.
- High Node Capacity: Supports up to 19 total node units (10 local + 9 remote) for large-scale I/O expansion.
FAQ
Q: What is the difference between AFS40S and AFS40D?
A: The AFS40S is a single (standard) field control unit. The AFS40D is a duplexed (redundant) field control unit with dual processors and power supplies for fault-tolerant operation.
Q: Can the AFS40S be upgraded to redundant operation?
A> The AFS40S is a single-unit design. For redundancy, replace it with the AFS40D duplexed field control unit.
Q: What is the maximum number of I/O modules per AFS40S?
A> Node capacity depends on the node unit type. The AFS40S supports up to 10 local node units, each accommodating multiple I/O modules. Total I/O count is determined by node unit configuration.
Installation Guide
- Install the FCU cabinet in a controlled environment within the specified temperature range.
- Connect Vnet cables to both primary and redundant network segments.
- Connect ESB bus cables to local node units.
- Wire the FCU status contact to an external alarm panel for failure indication.
- Verify battery voltage and memory backup status before commissioning.
Selection Tips
- System Generation: The AFS40S is designed for CENTUM CS 3000. For newer CENTUM VP installations, consider the AFS30S or AFS30D series.
- Redundancy Needs: For processes where controller failure is unacceptable, specify the AFS40D duplexed unit instead of the AFS40S.
- Node Planning: Calculate local vs. remote node requirements. Remote nodes require ER bus cables and are limited to 8 per ER bus segment.
Return policy
We aim to provide reliable products and a smooth purchasing experience. If there is a problem with your order, please contact us and we will assist according to our Refund Policy.
Shipping
We provide international shipping options to meet different delivery requirements. Please review details regarding methods and timelines in our Shipping Policy.
Warranty
We provide a 12-month warranty for all products, subject to normal use and proper installation.
You may also like
Product Guide
Mitigating SCADA Performance Drops During Shift Transitions
Mitigating SCADA Performance Drops During Shift Transitions
Optimizing SCADA Performance: Why Remote Clients Experience Lag
Optimizing SCADA Performance: Why Remote Clients Experience Lag