Skip to product information
Yokogawa F3YD64-1P Transistor Output Modules - 64-point

Yokogawa

Yokogawa F3YD64-1P Transistor Output Modules - 64-point

In stock
  • Manufacturer: Yokogawa

  • Product No.: F3YD64-1P

  • Product Type: Transistor Output

  • Product Origin: Japan,Singapore

  • Payment:T/T, Western Union

  • Weight: 800g

  • Shipping port: Xiamen

  • Warranty: 12 months

Special offer ends!
00 :
00 :
00

Product Overview

The Yokogawa F3YD64-1P is a 64-point sink-type transistor output module for the FA-M3 series, designed for high-density digital output applications. With 8 points per common and photocoupler isolation, it delivers fast, reliable switching of 24V DC loads at 0.1A per point. Built-in short-circuit protection and active clamp surge protection ensure robust operation in demanding industrial environments.

Key Specifications

  • Output Type: Transistor contact (sink type, NPN)
  • Number of Points: 64
  • Common Line Type: 8 points per common
  • Rated Load Voltage: 12 to 24V DC (10.2 to 26.4V DC operating range)
  • Maximum Load Current: 0.1A per point, 0.4A per common
  • Response Time: OFF→ON: 1 ms max; ON→OFF: 1 ms max
  • ON Voltage: 0.5V DC max
  • Off-State Leak Current: 0.1 mA max
  • Isolation: Photocoupler isolation, 1500V AC withstand
  • Protection: Short-circuit protector, overheat shutdown, active clamp surge protector
  • Current Consumption: 275 mA at 5V DC
  • External Power Supply: 12-24V DC, 95 mA
  • Connection: Two 40-pin connectors
  • Weight: 130 g

Compatibility & Applications

Compatible with all FA-M3 base modules. Ideal for high-density solenoid valve manifolds, LED indicator panels, small relay driving, distributed I/O systems, and high-speed production machinery requiring 64 outputs in a single slot.

FAQ

  • Q: What is the maximum current per common? A: 0.4A per common (8 points), so total module load should not exceed 3.2A (8 commons × 0.4A).
  • Q: Does it have short-circuit protection? A: Yes, each output group has short-circuit protection with automatic shutdown on fault detection.
  • Q: What connectors are required? A: The module uses two 40-pin connectors (typically Fujitsu FCN-707 series or equivalent).
  • Q: Can I drive relays directly? A: Yes, for small 24V DC relays, but ensure coil current does not exceed 0.1A per point.

Installation Guide

  1. Power off the FA-M3 system and external 24V supply.
  2. Insert F3YD64-1P into any available I/O slot.
  3. Connect 40-pin ribbon cables or pre-wired harnesses to the module connectors.
  4. Apply external 12-24V DC power to the module power terminals.
  5. Restore power and test outputs using ladder logic or WideField3 monitor function.
  6. Verify short-circuit protection by intentionally overloading one point (briefly) to test shutdown.

Selection Tips

  • Choose F3YD64-1P for maximum output density (64 points) in a single FA-M3 slot.
  • For 32-point applications, F3YD32-1P offers similar specifications with lower cost.
  • For higher current per point (1A), use F3YD08-6A (8 points) instead.
  • Ensure your external power supply can provide 95 mA module power plus total load current.
Return policy

​We aim to provide reliable products and a smooth purchasing experience. If there is a problem with your order, please contact us and we will assist according to our Refund Policy.

Shipping

We provide international shipping options to meet different delivery requirements. Please review details regarding methods and timelines in our Shipping Policy.

Warranty

We provide a 12-month warranty for all products, subject to normal use and proper installation.

You may also like